The Role of Biological Indicator for H2O2 vapor technology

from web site

Biological indicators (BIs) became the industry standard for verifying peroxide vapor (HPV) decontamination efficacy.

Biological indicators (BIs) are defined loosely as a characterized strain and population of a microorganism that will be wont to monitor the efficacy of a decontamination process. They still are considered the 'gold standard' as they demonstrate the power of the chosen method to inactivate highly resistant microorganisms. In addition to it, the strain, preparation, and presentation of the BI vary, counting on the technique the BI is meant for. This text will consider BIs designed for peroxide vapor (HPV) bio-decontamination.

 There is an increasing issue with inconsistency in BI batches and so-called 'rogue' BIs. Batch variability in BIs results in false positives, and although less easily detected false negatives. Inaccurate or unexpected results when re-validating HPV cycles can potentially have enormous consequences on BI users. Impacts range from having to repeat cycles to the scrapping of products and shutdown of facilities, which could pose a significant financial impact upon the user.

 

Different sorts of indicators in H2O2 Bio- decontamination

Chemical indicators (CI), biological indicators (BI), and enzyme indicators (EI) are used as a part of bio-decontamination cycle development studies. These studies typically consume vast numbers of indicators to work out the worst-case locations, representing specific areas in your environment that need the most extended periods of exposure to realize the target sterility assurance level (SAL).

 

In order to urge reliable measurement data, it's always best to live in a place rather than taking the air sample by employing a pump and tubing. You had to install the H2O2 sensor either inside the isolator or through the wall. Here is where indicators make sense: to work out where to put the sensor (i.e., the places it's most challenging for H2O2 to cover) inside the isolator. In addition to it, sometimes installing a sensor during this location isn't possible or wanted. During this case, a representative measurement position is going to be selected.

 

After cycle development studies, validation and re-validation studies are performed continuously. Indicators are included in invalidation and re-validation studies in worst-case locations to ensure that the method has achieved the target SAL. Inline measurement H2O2 sensors are often used continuously, from cycle development studies, through validation and re-validation runs, and through routine bio-decontamination processes. Inline sensor measurements, like those obtained with the sensor, display continuous measurement data that shows whether adequate ppm concentrations are achieved.

 

Continuous monitoring of an environment with a sensor during bio-decontamination allows you to decrease the number of indicators utilized in routine processes because accurate inline measurement data is available. Additionally, you'll monitor (and possibly also control) the condensation in your processes simultaneously.

 

In effect, continuous inline measurement shows you measurement values in real-time, ensuring the method goes well. Continuous H2O2 measurement also can be wont to control the vapor injection rate during bio-decontamination to take care of H2O2 vapor concentration at the specified level. With an inline sensor, you'll control the condensation level using the Relative Saturation parameter. (Read about the way to do that with the Relative Saturation parameter during this white book .) Finally, you're ready to import these data to your validation report easily. Proper documentation is significantly simplified.

In the end, there are numerous Indicators for the peroxide that used for various purposes. Right from chemical indicator to biological indicator, the different indicator has different purposes. Additionally, with their assistance, you will come to understand measurement value in real-time then on. However, it is not difficult to find out the information about indicators. All you need to do is search on the internet and collect the data.